Short answer
A 10kV industrial package should be quoted from one coordinated single-line diagram, with separate prices for MV switchgear, transformers, LV switchboards, any kiosk and auxiliary power. Confirm fault duty, protection, transformer interfaces, DC loads and installation boundaries before comparing totals; a budget offer is not an approved construction design.

Define one coordinated package, not unrelated equipment totals
A combined offer can cover incoming MV distribution, transformer interfaces and LV loads, but each system still needs a stated scope. Use the same drawing revision and equipment schedule across all suppliers.
- MV panels: incoming VCB, PT/metering, transformer outgoing feeders and any bus tie shown on the SLD.
- Transformers: specify quantity, kVA, voltage ratio, oil-filled or dry type, accessories and required documents.
- LV distribution: main boards, motor or compressor boards, ATS, compensation and auxiliaries as scheduled.
- List the kiosk, DC charger and batteries, control equipment, cables and site services separately; none is automatically included.
Package scope and responsibilities
| Package item | RFQ information | Boundary to confirm |
|---|---|---|
| MV switchgear and DC auxiliaries | Incomer, PT/metering and transformer feeders; relay, CT/PT and DC load data | Identify battery, charger, autonomy calculation and protection-study responsibilities |
| Transformers and kiosk | kVA, ratio, impedance, cooling, dimensions, losses and site layout | Separate transformer supply, enclosure, ventilation, cables, civil works and installation |
| LV boards and motor feeders | Load schedule, bus arrangement, motor duties, starting methods and brands | Identify MCC/PLC scope, control software, field equipment and commissioning |
Information to include in the RFQ
Related distribution equipment
Medium Voltage Switchgear
Incoming, metering, bus section and feeder panels with project-specific protection.
View productLow Voltage Switchgear
Main distribution, outgoing feeders and auxiliary power configured to the SLD.
View productControl Cabinets
PLC, motor starting, VFD and auxiliary control configurations for process loads.
View productPrefabricated Substation
Coordinated MV, transformer and LV package boundaries for project review.
View productHow to compare supplier quotations
Frequently asked questions
Sources and scope
JCON ELEC prepared this procurement checklist to organize equipment, document and interface requirements. Product pages describe equipment families; cited standards and manufacturer material are technical references, not proof of JCON certification, authorization or completed projects. Final ratings, compliance, responsibilities and delivery scope require approved project documents and an agreed offer.
- JCON ELEC prefabricated substation equipment
- JCON ELEC technical and commercial proposal checklist
- IEC 62271-200: AC metal-enclosed switchgear scope
- IEC 61439-2: power switchgear and controlgear assembly scope
Continue reading
Send your project requirements
Send the single-line diagram, equipment list, required brands, site conditions and destination for a project-based review.